Welcome
Our company deals with the distribution of laboratory products and provides services related to laboratory devices. The satisfaction of our customers is a priority for us, so the distribution of reliable, high-quality products is the most important aspect. Our service is characterized by fast, precise work and its quality is confirmed by our constantly expanding customer base. Our employees are always at your disposal with a high level of professional knowledge.
Products
- LAB Services Kft. has several decades of experience in service activities, in the accurate and precise execution of service activities. Our company undertakes the preventive maintenance, occasional repair and even qualification of the devices we sell. Our service engineers have manufacturer qualifications. In addition, we undertake the repair, maintenance and verification of mainly gas and liquid chromatography products not purchased from us, if the purchase of the parts can be solved.
- The most common tasks:
- - Installation
- - IQ/OQ/PQ
- - training
- - education
- - software update
- - maintenance
- - repair
- Contact us if you have any questions.
- Attila Takács - service manager
- Mobile: +36 20 291 2899
- E-mail: info@labservices.hu
The product groups are available by clicking on the image
Flash and Preparative Chromatography
puriFlash® XS 520
- - Control computer: Shuttle PC - Win 10, i7, 8 GB RAM
- - Pump
- - UV detector 200 - 400 nm (expandable 200 - 800 nm)
- - Fraction collector
- - Eluent storage with remedial safety piping
- - Built-in column holder
- - Stainless steel connector (54 mm)
- - Flow rate range: 1 mL/min - 300 mL/min
- - Optimum flow rate up to 800 g columns
- - Pressure range: 0 - 20 bar
- - Quaternary gradient mixing
- - Air cleaning (column drying)
- - Injection methods: Liquid or solid
- - On-line spectrum recording
- - Sample collection based on multiple wavelengths or scans
- - Normal Phase (NP) - 15-25-30-40-50 μm
- - Reverse Phase (RP) 15-30-50 μm
- - Fraction collector: 112 test tubes (18x150 mm) - other sizes available
puriFlash® 5.020 - puriFlash® 5.050 - puriFlash® 5.015‐XL
- - Control computer Shuttle PC - Win 10, i7, 8 GB RAM
- - Pump
- - UV detector 200 - 400 nm (expandable 200 - 800 nm)
- - Fraction picker
- - Eluent storage tray with remedial safety piping
- - Built-in column holder
- - Built-in Dry-load holder
- - Flow rate range: 1 mL/min - 825 mL/min (different for each device)
- - Optimum flow rate up to 1600 g columns
- - Pressure range: 0 - 50 bar (different for each device)
- - Quaternary gradient mixing
- - Air cleaning (column drying)
- - Injection methods: Liquid or solid
- - On-line spectrum recording
- - Sample collection based on multiple wavelengths or scans
- - Normal Phase (NP) - 15-25-30-40-50 μm
- - Reverse Phase (RP) 15-30-50 μm
- - Fraction collector: 132 test tubes (18x150 mm) - other sizes available
- - RFID technology - automatic column, Dry-load, Fraction picking rack recognition
puriFlash® 5.250 - puriFlash® 5.400UV
- - Control computer Shuttle PC - Win 10, i7, 8 GB RAM
- - Pump
- - UV detector 200 - 400 nm (optional 200 - 800 nm)
- - ELSD detector (optional)
- - Fraction picker
- - Eluent storage with remedial safety piping
- - 2 built-in column holders
- - 2 built-in Dry-load holders
- - Flow rate range: 1 mL/min - 250 mL/min (different for each device)
- - Optimum flow rate up to preparative columns with an internal diameter of 80 mm
- - Pressure range: 0 - 400 bar (different for each device)
- - Quaternary gradient mixing
- - Air cleaning (column drying)
- - Injection methods: Automatic liquid, solid, loop injection
- - On-line spectrum recording
- - Sample collection based on multiple wavelengths or scans
- - Normal Phase (NP) - 5-15-25-30-40-50 μm
- - Reverse Phase (RP) 5-10-15-30-50 μm
- - Fraction collector: 132 test tubes (18x150 mm) - other sizes available
- - RFID technology - automatic column, Dry-load, injection loop, fractionator rack recognition
puriFlash® 5.250P
- - Control computer Shuttle PC - Win 10, i7, 8 GB RAM
- - Pump
- - UV detector 200 - 400 nm (optional 200 - 800 nm)
- - ELSD detector (optional)
- - Fraction picker
- - Eluent storage with remedial safety piping
- - 2 built-in column holders
- - 2 built-in Dry-load holders
- - Flow rate range: 1 mL/min - 125 mL/min (different for each device)
- - Optimum flow rate up to preparative columns with an internal diameter of 60 mm
- - Pressure range: 0 - 250 bar (different for each device)
- - Quaternary gradient mixing
- - Air cleaning (column drying)
- - Injection methods: Automatic liquid, solid, loop injection
- - On-line spectrum recording
- - Sample collection based on multiple wavelengths or scans
- - Normal Phase (NP) - 5-15-25-30-40-50 μm
- - Reverse Phase (RP) 5-10-15-30-50 μm
- - Fraction collector: 132 test tubes (18x150 mm) - other sizes available
- - RFID technology - automatic column, Dry-load, injection loop, Fraction collection rack
UV Vis - ELSD - MS-HMW & MS Splitter - Differential Refractomeer
- UV-Vis Detector
- - Optical cell size: 0.3 mm - 1.0 mm - 1.3 mm (variable)
- - UV detector 200 - 400 nm (optional 200 - 800 nm)
- - UV scanning with "DAD technology" on the entire wavelength
- - Real-time On-line spectrum recording
- iELSD (Evaporative Light Scattering Detector)
- - Extremely sensitive photodiode structure
- - gas inlet pipe, drain pipe for liquids, gas discharge pipe
- - Light source: LED (470 nm)
- - Temperature control from room temperature to -100 °C
- - Minimum required gas pressure: 1 - 1.5 L/min - 1 bar
- - Purification of raw samples from a few milligrams to hundreds of grams
- - Dynamic Split: 40 μL/min sample flow rate into the ELSD
- - Sensitivity: <100 ng caffeine (LOD)
- - Automatic gain control (SaGa)
- - Low temperature technology
- - Specially developed for cleaning
- MS, MS-HWM, MS-Splitter
- - ESI, APCI, APCI-ASAP
- - Flow ESI: 10 μL - 1 mL
- - Flow APCI: 10 μL - 2 mL
- - Flow ASAP: 10 μL - 2 mL
- - puriFlash MS range: 10-1200 m/z
- - puriFlash MS-HWM range: 10-2000 m/z
- - Data collection frequency 10,000 m/z per second
- - Sensitivity: 10 pg reserpine (FIA injection of 5 μL)
puriFlash® XS-VAP - Evaporator: PuriVap 6 - TLC Plate Reader
- puriFlash® XS-VAP
- - Nitrogen flow control with the manometer on the device
- - Run up to 90 samples in parallel
- - Built-in control screen (for programming the vaporization)
- - Temperate water bath
- - Manual needle release system
- - Sample volume between 1ml - 250ml:
- 250 mL bottle with 1 mL restriction
- 250 mL bottle without restriction
- 18 x 150 mm (25 ml test tube)
- 16 x 150 mm (22 ml test tube)
- 16 x 100 mm (12 ml test tube)
- 13 x 100 mm (10 ml test tube)
- 17x60mm (8mL vial)
- 15x45mm (4mL vial)
- 12 x 32 mm (2mL vial)
- Eppendorf 2 mL
- Other sizes are available on request
- - Gas supply maximum 6 bar (0.6 MPa), Recommended: 3 bar
- Evaporator: PuriVap 6
- - Unique regulation of nitrogen supply
- - simultaneous evaporation of up to 6 samples
- - Flow APCI: 10 μL - 2 mL
- - Built-in screen for temperature control (indicates actual and target value)
- - Single aluminum heating block
- - 6 aluminum adapters for test tubes
- - 6 measuring vials of 40 ml 6 stainless steel needles (the height of the needles can be adjusted individually)
- - Corrosion-resistant parts made of PTFE
- - Sample volume between 1ml - 60ml:
- 28 x 140 mm (60 ml vial)
- 28 x 115 mm (40 ml measuring vial)
- 28 x 95 mm (40 ml vial)
- 18 x 150 mm (25 ml tube)
- 16 x 150 mm (22 ml tube)
- 16 x 100 mm (12 ml tube)
- 13 x 100 mm (10 ml tube)
- 12 x 32 mm (2 ml vial)
- - Nitrogen gas supply maximum 2 bar (0.2 MPa)
- TLC Plate Reader
- - Read any TLC plate
- - TLC size up to 8.5 cm wide and 12.5 cm high
- - Illumination with white light (2 lamps), UV 254 nm (2 lamps) and UV 366 nm (2 lamps)
- - Control with separate software : "TLC-FlashReader" software, which allows displaying and archiving TLC discs
- - Or control connected with InterSoft® X software
- - Automatically turn off the lights when the drawer is opened to protect the user from UV radiation
- - Removable TLC plate holder for easy maintenance
- - TLC-FlashReader can be connected to all our puriFlash® Gen 5, puriFlash® XS 520 Plus and puriFlash® 535-XL devices
- - Can be connected to any Windows 10 computer for separate use with "TLC-FlashReader" software
puriFlash® AS-1 Autosampler - Dryload cartridges - Injection loops
- puriFlash® AS-1 Autosampler
- - Injection volume: 500 μL - 50ml
- - Sample injection, solvent tube and needle washing,
- - Syringe pump with 10 ml or 25 ml syringe (optional)
- - Flushing station, flushing pipe
- - Test tube holders: 13 x 150 mm | 18 x 150 mm | 16 x 150 mm 21 x 150 mm | 25 x 150 mm | 28 x 150 mm
- - Holder stand for 250 ml bottles
- - Holder stand for HPLC vials
- - Sample holders can be tempered between 0 °C - 70 °C (optional)
- Dryload cartridges
- - Dry-load columns allow the crude sample to be injected directly into the mobile phase, regardless of whether it is soluble or not. Compared to liquid injection, solid sample application avoids the diffusion of the raw sample on the column. This improves the resolution, thereby making the cleaning of the sample more efficient.
- - Available in stainless steel and PTFE versions
- - Luer-lock Inlet & outlet
- - available from 4 g to 300 g
- - Compatible with all flash chromatography systems
- Injection Loops
- - High quality stainless steel
- - The ends of the loop are cut perfectly perpendicular
- - Full or partial injection of the loop volume
- - The inserted loop can be automatically recognized by RFID in the IntersoftX software
- - Available loop sizes: 100 µl, 250 µl, 500 µl, 1 ml, 2 ml, 5 ml, 10 ml, 20 ml, 40 ml, 50 ml
ECOM modular systems
- ECOM is a manufacturer of analytical, flash and preparative chromatography devices, as well as chromatography units and modules (pump, detector, fraction collector, etc.).
- Whether for preparative or analytical use, customers can choose from complete laboratory chromatography systems and modular units such as HPLC detectors, pumps, fraction collectors and other peripherals such as custom flow cells, control software and many other related products.
Analytical, Flash and Preparative columns, silicas
Analytical HPLC columns
- Uptisphere® CS Evolution
- Core Shell columns for fast and highly efficient identification and quantification of small molecules.
- Uptisphere® Strategy™
- (U)HPLC, large surface analytical and precursor columns for the identification, quantification and purification of small molecules and pharmaceutical compounds.
- Uptisphere® 120Å
- HPLC and prep LC columns for the identification and quantification of small molecules and pharmaceutical compounds.
- Empty HPH™ Analytical Columns
- HPLC and UHPLC compatible
- Maximum pressure: 1200 bar
Flash columns
- puriFlash®
- Analytical, Prep LC and Flash columns for routine separations, which facilitate method transfer during the purification of small organic molecules.
- puriFlash® Bio
- (U)HPLC, Analytical, Prep LC and Flash columns for the identification, quantification and purification of peptides, polypeptides and proteins at high and low pH.
- Uptisphere® Bio
- X-serie™ Uptisphere® 300Å Uptisphere® TP
- HPLC and Prep LC columns for the identification and quantification of proteins, peptides and polypeptides at high and low pH.
Empty Flash cartridges
- SuperSep™ empty Flash cartridges
- The empty Flash cartridges manufactured by Luknova are popular among chemists, as they satisfy all individual needs, their installation is easy and the filled column is leak-free.
- Size range available: from 4 g to 1500 g
Preparative HPLC columns
- LC Preparative columns
- Preparative columns manufactured by Advion-Interchim Scientific are suitable for the purification of samples from 0.5 mg to 1 g.
- Available sizes: 10 - 50.8 mm inner diameter
- Each column has an extremely smooth internal surface (typically 8 μ in. Ra), which greatly reduces resistance problems and preserves column efficiency.
DAC columns
- Dynamic axial compression column, DAC
- The DAC (Dynamic Axial Compression) column is a unique combination of a preparative column and a filling system.
- It is very simple, the column can be used in-line when it is full. The column piston creates a constant pressure on the phase bed, which prevents the charge from collapsing or rapidly deteriorating.
- In order to achieve high performance, it can be filled with small particle size filler.
- Sizes:
- DAC50 - 50mm
- DAC80 - 80mm
- DAC100 - 100mm
- DAC150 - 150mm
- DAC200 - 200mm
Glass columns
- SNAP® glass columns manufactured by Essential Life Solutions are very suitable for low and medium pressure separations. Depending on the type, the bed length of the columns can be varied with one or two pistons, and they are easy to fill.
- Available sizes: 10 - 50 mm internal diameter
- Bed length: 125 - 1000 mm
- Pressure: up to 13 - 40 bar
GC columns
- Advion-Interchim Scientific has developed UptiBond capillary columns for gas chromatography procedures.
- Areas of application:
- Toxicology
- Analysis on organic tissues
- Drug screening
- Doping screening
- Environmental analyses
- Residual aromatic hydrocarbons
- Organochlorine, nitrogenous and chlorinated pesticides
- Semi-volatile compounds, phenols
- Volatile organic acids
- Chemistry
- Analysis of hydrocarbons, alcohols, organic acids, volatile amines, glycols, aldehydes, solvents
Flash-Prep silica
- Advion-Interchim Scientific offers regular, reversed-phase, and other modified silica gels specifically for preparative and flash chromatographic purification.
- puriFlash® silica gels are available in several particle sizes from 5 μm to 50 μm.
- Scaling up is easy as it is possible to transfer the separation from the analytical column to the flash / preparative column while keeping the same type of charge.
Physical-Chemical Characterization
DVS Discovery
- - Temperature:
- Incubator Temperature range: 10°C - 70°C
- Incubator Temperature stability: ± 0.05°C
- Incubator Temperature accuracy: 0.01°C
- Pre-heater Temperature maximum 200°C
- Pre-heater Heating speed: 5°C/min
- - Gas flow regulation:
- High precision digital mass flow controllers
- Wide dynamic range - 1000:1
- Purge gas - Dry air or nitrogen
- - Relative humidity:
- Relative humidity range: 0-98% (at 10-45ºC)
- Relative humidity range: 0-85% (at 45-70ºC)
- Relative humidity resolution: ± 0.1%
- Relative humidity stability: ± 0.1% (over 6 hours)
- RH range accuracy: 10-45ºC ± 0.5%
- RH range accuracy: 45-70ºC ± 1%
- - Treatment of organic solvents:
- High precision digital mass flow controllers
- Sound velocity sensor for organic vapors
- Purge gas - Dry air or nitrogen
- Partial pressure range: 0-90%
- Partial pressure accuracy: 10-70°C ±1%
- In-line real-time Speed of Sound Sensor for organic vapor partial pressure (P/Po) measurements
- Control: with ±0.1% P/Po resolution
- Automatic zeroing of the Speed of Sound sensor before each experiment
- - Balance:
- Ultrabalance Low Mass:
- Maximum load: 1000 mg
- Weight change tolerance: ±150 mg
- Resolution: 0.01 μg
- Noise balance: ≤ 0.3 μg
- Ultrabalance High Mass:
- Maximum load: 5000 mg
- Weight change tolerance: ±1000 mg
- Resolution: 0.1 μg
- Noise compensation: ≤ 3 μg
- - Software:
- Basic software:
- Control software
- Standard Analysis Suite
- Optional software:
- Advanced Analysis Suite
- Isotherm Analysis Suite
- A 21CFR Part 11 software solution is available upon request for all DVS software
DVS Adventure
- - Temperature:
- Incubator Temperature range: 5°C - 85°C
- Incubator Temperature accuracy: ±0.1°C (at 5-60°C)
- Incubator Temperature accuracy: ±0.2°C (at 60-85°C)
- Pre-heater Temperature maximum 200°C
- Pre-heater Heating speed: 5°C/min
- The cover also provides protection against condensation
- - Gas flow regulation:
- High precision digital mass flow controllers
- Wide dynamic range - 1000:1
- Purge gas - Dry air or nitrogen
- For AQUEOUS Applications ONLY
- - Relative humidity:
- Relative humidity range: 0-98% (at 5-60ºC)
- Relative humidity range: 0-85% (at 60-85ºC)
- Relative humidity resolution: ± 0.1%
- Relative humidity stability: ± 0.5% (over 6 hours)
- RH range accuracy: 5-60ºC ± 0.5%
- RH range accuracy: 60-85ºC ± 1%
- - Treatment of organic solvents:
- DVS Adventure cannot be used with organic solvents
- - Balance:
- Ultrabalance Low Mass:
- Maximum load: 1000 mg
- Weight change tolerance: ±150 mg
- Resolution: 0.01 μg
- Noise balance: ≤ 0.3 μg
- Ultrabalance High Mass:
- Maximum load: 5000 mg
- Weight change tolerance: ±1000 mg
- Resolution: 0.1 μg
- Noise compensation: ≤ 3 μg
- - Software:
- Basic software:
- Control software
- Standard Analysis Suite
- Optional software:
- Advanced Analysis Suite
- Isotherm Analysis Suite
- A 21CFR Part 11 software solution is available upon request for all DVS software
DVS Endeavour
- - Temperature:
- Incubator Temperature range: 10°C - 70°C
- Incubator Temperature stability: ± 0.1°C
- Incubator Temperature accuracy: 0.1°C
- Pre-heater Temperature maximum 200°C
- Pre-heater Heating speed: 10°C/min
- The cover also provides protection against condensation
- - Gas flow regulation:
- High precision digital mass flow controllers
- Wide dynamic range - 1000:1
- Purge gas - Dry air or nitrogen
- - Relative humidity:
- Relative humidity range: 0-98% (at 10-45ºC)
- Relative humidity range: 0-85% (at 45-70ºC)
- Relative humidity resolution: ± 0.1%
- Relative humidity stability: ± 0.5% (over 6 hours)
- RH range accuracy: 10-60ºC ± 0.5%
- RH range accuracy: 60-70ºC ± 1%
- - Treatment of organic solvents:
- High precision digital mass flow controllers
- Sound velocity sensor for organic vapors
- Purge gas - Dry air or nitrogen
- Partial pressure range: 0-90%
- Partial pressure accuracy: 10-50°C ±1%
- In-line real-time Speed of Sound Sensor for organic vapor partial pressure (P/Po) measurements
- Automatic zeroing of the Speed of Sound sensor before each experiment
- - Balance:
- The device is equipped with 5 scales at the same time
- Ultrabalance Low Mass:
- Maximum load: 1000 mg
- Weight change tolerance: ±150 mg
- Resolution: 0.01 μg
- Noise balance: ≤ 0.3 μg
- Ultrabalance High Mass:
- Maximum load: 5000 mg
- Weight change tolerance: ±1000 mg
- Resolution: 0.1 μg
- Noise compensation: ≤ 3 μg
- - Software:
- Basic software:
- Control software
- Standard Analysis Suite
- Optional software:
- Advanced Analysis Suite
- Isotherm Analysis Suite
- A 21CFR Part 11 software solution is available upon request for all DVS software
DVS Vacuum
- - Temperature:
- Incubator Temperature range: 20°C - 70°C
- Incubator Temperature accuracy: ±0.1°C (at 20-70°C)
- Pre-heater Temperature maximum 400°C
- Pre-heater Heating speed: 10°C/min
- The cover also provides protection against condensation
- - Gas flow regulation:
- High precision digital mass flow controllers
- Wide dynamic range - 1000:1
- Purge gas - Dry air or nitrogen
- - Relative humidity:
- Relative humidity range: 0-90% (at 20-70ºC)
- Relative humidity resolution: ± 0.05%
- Relative humidity stability: ± 0.5%
- RH range accuracy: 20-70ºC ± 0.5%
- - Treatment of organic solvents:
- High precision digital mass flow controllers
- Adsorption types: organic solvents, e.g. water, toluene, methanol, ethanol, benzene, acetaldehyde
- Gases: CO2, N2, 2000 ppm NH4, H2S
- Butterfly valve (additional control):
- The butterfly valve regulates the amount of vapors and gases in the system by opening and closing depending on the pressure inside the chamber, while keeping the total pressure at a constant level.
- - Pressure measurement:
- With 1000 Torr Baratron pressure gauge:
- Full scale from 0.01 to 1000 Torr (standard)
- With a 10 Torr Baratron pressure gauge:
- Full scale from 0.005 to 10 Torr (standard)
- Other ranges are available on request: (100 and 500 Torr)
- Accuracy: ±0.5
- Resolution: 0.01% of full scale
- - Vacuum pressure measurement:
- Vacuum pressure: full scale from 1×10-8 Torr to 760 Torr
- - Balance:
- Ultrabalance Low Mass:
- Maximum load: 1000 mg
- Weight change tolerance: ±150 mg
- Resolution: 0.01 μg
- Noise balance: ≤ 0.3 μg
- - Software:
- Basic software:
- Control software
- Evaluation software
Inverse Gas Chromatography-Surface Energy Analyzer (iGC-SEA)
- What is iGC-SEA?
- The iGC-SEA or Inverse Gas Chromatography Surface Energy Analyzer is an instrument that uses the principle of iGC. At the heart of its innovation is a patented injector-dispenser system that generates precise solvent pulse doses over a wide concentration range, resulting in isotherms with unprecedented high and low sample surface coverage. This makes it possible to accurately determine the distribution of surface energy heterogeneity.
- - Temperature:
- Column space Temperature range: 20°C - 150°C
- Column space Temperature accuracy: ±0.5°C
- The cover also provides protection against condensation
- - Gas flow regulation:
- Unique gas phase injection system with 1:4000 injection volume ratio
- Carrier gas – helium or nitrogen
- With a humidity option, even for wet applications
- - Relative humidity:
- Relative humidity range: 0-90%
- Relative humidity resolution: ± 1%
- Relative humidity stability: ± 1%
- RH range accuracy: ± 1.5%
- - Treatment of organic solvents:
- 12 solvent containers
- Easily accessible solvent containers
- Temperature-controlled solvent space for vapor stability
- - Additional features:
- H2 and organic vapor leak detector
- Flame ionization detector (FID) with adjustable sensitivity
- It can be used with 2 sample columns
- - Software:
- Basic software:
- Control software
- Evaluation software
- A 21CFR Part 11 software solution is available upon request
Flow and Batch Reactors
General characteristics of ATLAS HD reactor systems
(The specifications of different systems are different. Check details.)
- - Temperature range:
- Temperature range: -90°C - +250°C*
- *(The normal temperature range is between -40 and 200°C. For temperatures outside this range, additional accessories are required.)
- - Reactor vessel size:
- 50 mL - 5 L
- With a DN80 collection system: 50 mL - 2 L
- With DN150 collection system: 1 L - 5 L
- - Pressure range:
- Vacuum: ≤50 mbar. Max. pressure: 200 bar**
- **Atlas HD Potassium: Vacuum (≤50 mbar) – 250 mbar.
- (Lower vacuum is available with additional accessories.)
- Atlas HD 3 Bar: Vacuum (≤1mbar) – 3 bar
- Atlas Sodium 200 Bar (stainless steel): Vacuum (≤1 mbar - 200 bar)
- - Mixing motor:
- Stirring motor torque: 11 N/cm***
- *** Mixer motors with higher torque are also available
- - Dosage options:
- 0.5 μL - 20 ml/min - with Atlas syringe pump
- 5 μL - 200 ml/min - with Atlas XL syringe pump
- - Temperature-dependent dosing
- - pH-controlled dosing
- - Automatic dosing of up to 6 samples with a single syringe
- - Dosing by mass
- - Can be automated: using ATLAS PC software
- - Touch screen control
General characteristics of ASIA reactor systems
(The specifications of different systems are different. Check details.)
- Temperature Range:
- -100°C to +250°C
- Flow Rate:
- 1 µL/min to 10 mL/min per pump channel
- Residence Times:
- 1 second to several hours
- Pressure Range:
- 0 to 20bar (300psi)
- Liquid Phase Reactor Volumes:
- 62.5 µL, 250 µL, and 1,000 µL for glass microchips 4 mL and 16 mL for tube reactors
- Solid Phase Reactor Volumes:
- 0.7 mL, 2.4 mL, 5.6 mL, and 12 mL
- Wetted Parts:
- Glass, PTFE and PCTFE (stainless steel and hastelloy possible)
- Mixing:
- Rapid diffusion mixing
- Production Volumes:
- Milligrams to Kilograms
General characteristics of ORB reactor systems
(The specifications of different systems are different. Check details.)
- - Temperature range:
- Temperature range: -90°C - +250°C*
- *(The normal temperature range is between -40 and 200°C. For temperatures outside this range, additional accessories are required.)
- - Reactor vessel size:
- 100 mL - 10 L
- Jacketed reactor with vessel: 100 mL - 10 L
- Vacuum jacketed reactor with vessel: 100 mL - 5 L
- - Pressure range:
- Vacuum: ≤50 mbar Max. pressure: 200 bar**
- **Lower vacuum can be achieved with additional accessories.
- - Mixing motor:
- Mixer motor torque: up to 200 N/cm
- Mixer motor speed:
- - 500 rpm continuous
- - 800 rpm intermittent
- - Dosage options:
- 0.5 μL - 20 ml/min - with Atlas syringe pump
- 5 μL - 200 ml/min - with Atlas XL syringe pump
- - Temperature-dependent dosing
- - pH-controlled dosing
- - Automatic dosing of up to 6 samples with a single syringe
- - Dosing by mass
- - Can be automated: using ATLAS PC software
General characteristics of ORB PILOT reactor systems
(The specifications of different systems are different. Check detail)
- - Temperature range:
- Temperature range: -40°C to +235°C
- - Reactor vessel size:
- 10 L - 50 L
- Jacketed reactor with vessel: 10 L - 50 L
- Vacuum jacketed reactor with vessel: 10 L - 30 L
- - Pressure range:
- Vacuum: ≤50 mbar Max. pressure: 250 mbar
- - Mixing motor:
- Mixer motor torque: up to 400 N/cm
- Mixer motor speed:
- - 500 rpm continuous
- - 800 rpm intermittent
- - Dosage options:
- 0.5 μL - 20 ml/min - with Atlas syringe pump
- 5 μL - 200 ml/min - with Atlas XL syringe pump
- - Temperature-dependent dosing
- - pH-controlled dosing
- - Automatic dosing of up to 6 samples with a single syringe
- - Automatic dosing according to volume
Costum reactors and reactor systems
- Syrris' R&D team regularly works with chemists and chemical engineers in a variety of industries to design, prototype, test, and manufacture custom components for their batch, continuous flow, and scale-up chemical reactor systems.
- The development and design team of Syrris, as well as the relevant regional sales manager, maintain regular contact with the customer during the unique component design - manufacturing - testing process, in order to ensure that the purpose of the individually created component is fully realized.
Sample preparation, SPE, Evaporators
Sample preparation
- Filtration through a special membrane is an essential step in sample preparation to remove solid particles from the suspension.
- This covers various application areas:
- In biology or biochromatography, this technique removes viruses, bacteria, or even isolates high molecular weight proteins from the matrix. Filters are usually used for sterilization.
- Their area of use is very wide:
- Agriculture, cosmetics industry, analytics, etc.
SPE
- The preparation of the matrices to be treated (blood, plasma, water, etc.) requires different techniques: filtration, dialysis, liquid-liquid extraction, solid phase extraction (SPE). Of these, solid phase extraction is certainly the technique that has developed the most in recent years.
- SPE is now present in most laboratories and allows efficient sample purification and concentration prior to HPLC, GC or GC/MS analysis. Therefore, new technological innovations have entered the field of SPE, such as high surface area polymers, ion exchange polymers and pure spherical silica gels.
PuriFlash R-Vap rotary evaporator
- Features of main unit:
- Flask volume: maximum 3 L
- Rotation speed range: 20 - 300 RPM
- Direction of rotation: clockwise / counter-clockwise
- Display: LCD display
- Vertical adjustment range: 160 mm
- Immersion angle: 0° - 60°
- Condenser: Vertical type - 1,200 cm2 (optionally 1,500 cm2)
- Glass quality: Borosilicate glass
- Heating unit properties:
- Temperature range: From room temperature to - 230°C
- Temperature control mode: PID (digital display)
- Timer: Yes
- Overheating protection: Yes
- Temperature accuracy: ± 1°C water - ± 2°C oil
- Capacity: 5 L
- Bath material: 304 stainless steel with PTFE coating
- Cooling system (chiller) properties:
- Temperature range: between -5°C and 35°C
- Temperature stability: ± 0.3°C
- Display: PID (digital display)
- Cooling power: 500 W at 25°C
- Pump capacity: 3 L/min at 10 psi
- Pump type: magnetic drive
- Liquid tank volume: 2.5 liters
- Refrigerant: R134A
- Vacuum pump properties:
- Several types: puriFlash® P-005 / puriFlash® P-020 / puriFlash® P-250
- Maximum vacuum flow rate: 20 L/min / 18 L/min / 30 L/min
- Maximum vacuum: 5 mbar / 20 mbar / 250 mbar
- Vacuum regulation: yes - manual
- Vacuum display: yes
XS-Vap laboratory evaporator
- puriFlash® XS-VAP
- - Nitrogen flow control with the manometer on the device
- - Run up to 90 samples in parallel
- - Built-in control screen (for programming the vaporization)
- - Temperate water bath
- - Manual needle release system
- - Sample volume between 1ml - 250ml:
- 250 mL bottle with 1 mL restriction
- 250 mL bottle without restriction
- 18 x 150 mm (25 ml test tube)
- 16 x 150 mm (22 ml test tube)
- 16 x 100 mm (12 ml test tube)
- 13 x 100 mm (10 ml test tube)
- 17x60mm (8mL vial)
- 15x45mm (4mL vial)
- 12 x 32 mm (2mL vial)
- Eppendorf 2 mL
- Other sizes are available on request
- - Gas supply maximum 6 bar (0.6 MPa), Recommended: 3 bar
PuriVap 6 evaporator
- Evaporator: PuriVap 6
- - Unique regulation of nitrogen supply
- - simultaneous evaporation of up to 6 samples
- - Flow APCI: 10 μL - 2 mL
- - Built-in screen for temperature control (indicates actual and target value)
- - Single aluminum heating block
- - 6 aluminum adapters for test tubes
- - 6 measuring vials of 40 ml 6 stainless steel needles (the height of the needles can be adjusted individually)
- - Corrosion-resistant parts made of PTFE
- - Sample volume between 1ml - 60ml:
- 28 x 140 mm (60 ml vial)
- 28 x 115 mm (40 ml measuring vial)
- 28 x 95 mm (40 ml vial)
- 18 x 150 mm (25 ml tube)
- 16 x 150 mm (22 ml tube)
- 16 x 100 mm (12 ml tube)
- 13 x 100 mm (10 ml tube)
- 12 x 32 mm (2 ml vial)
- - Nitrogen gas supply maximum 2 bar (0.2 MPa)
ICP-MS
- ICP-MS:
- Advion Interchim Scientific has created the SOLATION® ICP-MS – the perfect tool for multi-element analysis, providing high-sensitivity measurement of trace elements from a wide range of matrices. With easy-to-use, intuitive software, the SOLATION® ICP-MS is an ideal tool for environmental, pharmaceutical, food safety, agricultural, cannabis, hemp and clinical laboratories.
Laboratory accessories, spare parts, vials, etc.
Vials, caps and glasswares
- Interchim® - UptivialTM
- Our company offers a wide range of sample vials, whether for liquid chromatography or gas chromatography separation. More information can be found in the catalog available by pressing the details button.
Connectors, tubings, valve
- Tubings
- Low pressure
- PTFE (PolyTetraFluoroEthylene)
- ETFE (EthylTriFluoroEthylene)
- FEP (Fluorinated Ethylene Propylene)
- PFA (PerFluoro Alkoxyalkane)
- Nylon
- Metal tubes
- Stainless steel
- Pre-cut stainless steel, flexible
- PEEK tubes
- Striped color coded PEEK tubing
- Solid color coded PEEK tubing
- Thermo formed PEEK tubing
- Tubing cutter
- Stainless steel
- PEEK
- Fittings
- Low pressure fittings
- Flanging-Tool, flanged fittings
- Flangeless fittings
- PEEK & Barbed adapters
- Fittings and valves
- Swagelok Valves
- Swagelok Fittings
- PEEK Fittings
- Uptisûr, PEEK simple, No-Twist
- Hexagonal head, identification ring
- PEEK 2 pieces, unions
- PEEK tees, crosses, mixers, couplers
Safety caps
- SafetyCaps:
- Safe solvent supply for any HPLC/UHPLC system.
- Organic solvents are toxic, flammable and vapors can escape even through the smallest openings.
- The S.C.A.T. system guarantees a safe and fixed connection of all pipes and blocks harmful vapors for your safety without compromising the mixing ratio of the mobile phase.
- The vent valves ensure safe pressure equalization without creating under- or over-pressure in the solvent bottles.
- Due to its design and components, the V2.0 vent valve is the safest valve on the market. It can be used up to a flow rate of 400 ml/min.
- It is equipped with a PTFE filter to prevent particles from entering the mobile phase when the valve is opened.
- In addition, it is possible to inject gas or connect a tube to a desiccator using the Luer lock socket.
HPLC accesories, in-line filters, filters
- HPLC accessories
- Mobile phase filters - Last drop, biocompatible
- In line Filters - Very high pressure, preparative
- Liquid flowmeter
- Empty HPLC columns
- Stainless steel frits and Saintless frits with PEEK ring
- Biocompatible empty HPLC columns
GC accesories
- Gas filters:
- Purigaz (base plate and filters)
- Purigaz (High Flow base plate and filters) & accessories
- Click-On
- Click-On Big trap
- Leakdetectors
- GC ferruls
- Septas
- GC tools and glass wool
Tools
- Szerszámok és eszközök
- Hex and Torx keys, screwdrivers, spanners
- Wrenches, pliers, tweezers
- Screwdrivers, Cutters, Magnets, Magnetic tools, Drills
- Tool kits
Bioreagents, Protemics, Cell Biology
- Protein and peptide research
- There are several techniques for performing protein and polypeptide assays in solutions and gels. Among these techniques, colorimetric tests are widely used due to their ease of use and sensitivity. The most universal and accurate is the "BC Assay".